Level 1 Standard (Air-cooled) |
Level 2 Extended Temperature (Air-cooled) |
Level 3 Rugged (Air-cooled) |
Level 4 Rugged (Conduction-cooled) |
Level 5 Rugged (Conduction-cooled) |
動作温度 |
0~+55℃ with 300 linear ft./min. airflow |
-20~+65℃ with 300 linear ft./min. airflow |
-40~+70℃ with 600 linear ft./min. airflow |
-40~+75℃ with 600 linear ft./min. airflow |
-40~+85℃ at the thermal interface |
保存温度 |
-50~+100℃ |
-50~+100℃ |
-50~+100℃ |
-50~+100℃ |
-50~+100℃ |
振動 |
0.002g/Hz from 10 to 2000Hz random and 2g sinusoidal from 5 to 500Hz |
0.002g2/Hz from 10 to 2000Hz random and 2g sinusoidal from 5 to 500Hz |
0.04g2/Hz 20 to 2000Hz, with a flat response to 1000Hz, 6dB/octave roll-off from 1000 to 2000Hz |
Random, 0.1g2/Hz from 15 to 2000Hz per MIL-STD- 810E Fig 514.4 – 8 for high performance aircraft. ~12g RMS |
Random, 0.1g2/Hz from 15 to 2000Hz per MIL-STD- 810E Fig 514.4 – 8 for high performance aircraft. ~12g RMS |
衝撃 |
20g peak sawtooth, 11mS duration |
20g peak sawtooth, 11mS duration |
20g peak sawtooth, 11mS duration |
40g peak sawtooth, 11mS duration |
40g peak sawtooth, 11mS duration |
湿度 |
Up to 95% RH |
Up to 95% RH with varying temperature, 10 cycles, 240 hours |
Up to 95% RH with varying temperature, 10 cycles, 240 hours |
Up to 95% RH with varying temperature, 10 cycles, 240 hours |
Up to 95% RH with varying temperature, 10 cycles, 240 hours |
アプリケーション |
Commercial grade, for use in benign environments and software development applications. |
Similar to standard, conformally-coated for added protection and temperature characterized. |
Wide temperature, conformally-coated for added protection. Optional Environment Stress Screening (ESS). |
Designed for severe environment applications with high levels of shock and vibration, small space envelope and restricted cooling. Conformally-coated for added protection. Optional Environment Stress Screening (ESS). |
Designed for severe environment applications with high levels of shock and vibration, small space envelope and restricted cooling. Conformally-coated for added protection. Optional Environment Stress Screening (ESS). |